APSPDCL AE Electrical Syllabus| Sample Question Paper & Answers
APSPDCL Assistant Engineer AE Electrical
Duration of the test is 2hrs (120 minutes)
The question paper consists of 100 multiple choice questions
Minimum qualifying marks in APSPDCL written test: OC – 40%, BC – 35%, SC/ST – 30%, PH – 30%
Click here for APSPDCL Assistant Engineer Syllabus – Electrical
APSPDCL Assistant Engineer AE Electrical Sample Question Paper & Answers
1. The connection used for 11Kv/440V distribution transformer is
A. Delta-delta B. Star-delta C. Delta-star D. Star-star
2. In short circuit test of transformer iron losses are neglected because
A) mutual flux is small B) copper losses are high C) secondary current is small D) primary current is small
3. The rating of lightning arrestor used for protection of 132KV transformer is
A) 132 kv, 5kA B) 120 kv, 10KA C) 120 kv, 5kA D) 76.2 kv, 10kA
4. The speed time curve used for main line transaction is
A) trapezoidal B) triangular C) quadrilateral D) rectangular
5. A digital-to-analog converter with a full-scale output voltage of 3.5 V has a resolution close to 14m V. Its bit size is
A) 4 B) 8 C) 16 D) 32
6. The low voltage winding of a 400/230V,single phase 50 hz transform er is to be connected t o a 25hz, the supply voltage should be
A) 50V B) 20V C) 115V D) 225V
7. The form factor for sinusoidal waveform is
1) 1 .00 2) 1.11 3) 1.732 4) 2.2
8. The rotor resistance and reactance of a three-phase induction motor is 0.2 ohm and 2 ohm respectively. The per unit slip corresponding to maximum torque is equal to
1) 9.02 2) 0 .01 3) 0.1 4) 0.2
9. Load factor is defined as the ratio of
1) Average power demand to maximum power deamand 2) Minimum power demand to maximum power deamand 3) Maxi mum power demand to minimum power deamand 4) Average power demand to minimum power deamand
10. The unit of luminous flu x is
1) Lux 2) candle power 3) metre cancle 4) lumen
11. For 1 32 KV transmission line, the insulators commonly used are
1) Strain type 2) Pint type 3) Suspension type 4) Shackle type
12. The insulation strength of an EHV transmission line is mainly governed by
A) load power factor B) switching over-voltages C) harmonics D) corona
13. A 400/100V, 10KVA two winding transformer is re connected as an auto transformer is re connected as an auto transformer across a suit able voltage source. The maximum rating of such an arrangement could be
A) 50 KVA B) 150 KVA C) 550 KVA D) 750 KVA
14. For the equation x(t)+3 x(t) +2x(t) = 5, the solution x (t) approaches which of the following values as t tends to infinity ?
A) 0 B) 5 C) 25 D) 10
15. In a transformer the voltage regulation will be zero when it operates at
(A) unity p.f. (B) leading p.f. (C) lagging p.f. (D) zero p.f. leading.
Ans: B
APSPDCL Assistant Engineer Answer Keys
1.C 2.A 3.B 4.A 5.B 6.C 12.B 13.A 14.B 15.B
Similar Posts:
- APSPDCL AE 2012 (Electrical) Hall Tickets & Selection Procedure
- APPSC Assistant Engineer AE 2012 Paper Pattern & Syllabus
- Assistant Engineer GS & Civil/ Mechanical/ Electrical Question Papers & Key 2012
- APGENCO AE 2012 Electrical Question Paper & Answer keys
- EPFO Executive/ Assistant Engineer Recruitment 2013